Heavy Industrial & Commercial Wastewater Management.

TECP Series Outdoor Panel

The Tulsar Controls TECP Series Panel is the innovative and efficient way to manage the wastewater in your large building or facility.

Ideally suited for a heavy industrial, municipal, commercial or multi-residential setting, the TECP Series is a customizable control that boasts best-in-class diagnostic capabilities, remote alerts and automatic transfers, giving you peace of mind that if one pump fails your system will continue to operate while being serviced.
The automation of the TECP Series will ensure necessary staff, whether they are off-site or just in another part of the building, will be alerted by telephone, text message or email of a problem. The precise level control of the TECP can be cataloged with an analog read out.
Featuring a vandal-proof NEMA 4 enclosure and main disconnect, the TECP outdoor series boasts a safety hasp so that is can be secured with a padlock. A fully hinged inner door provides an extra layer of security and safety.
Meticulously hand assembled at the Tulsar Controls facility in Brantford, Ont., the advanced technology includes a visual high water alarm globe with an LED flasher, hands-off-auto switches and alarm test and acknowledge switches.
Optional Features for Alarms and Status Include:

  • Alarm Bell (Nema 1) (1)
  • Alarm Horn (Nema 4) (2)
  • Wet contacts for remote alarm (3)
  • Extra dry contacts for remote alarm (4)
  • Dry contacts for equipment status (5)
  • 4 Channel landline Autodialer with battery backup (6)
  • 8 Channel Cellular Autodialer with built in battery backup (7)
Optional Features for Pump Monitoring Include:

  • Pump seal leak alarm (Price is per pump) (8a-Single probe; 8b-Dual Probe; 8c- Single or Dual probe) (8)
  • Pump heat sensor cut-out – auto reset (Price is per pump) (9)
  • Pump heat sensor cut-out and alarm – auto reset (Price is per pump) (10)
  • Pump heat sensor lockout, transfer and alarm-manual reset (price is per pump) (Transfer on duplex panels only) (11)
  • Pump overload fault lockout, transfer and alarm- manual reset (price is per pump) (Transfer on duplex panels only) (12)
  • Pump undercurrent fault lockout and alarm- manual reset (Price is per pump) (Transfer on duplex panels only) (13)
  • Fuse blown fault lockout and alarm – manual reset (Price is per pump) (14)
  • Circuit breaker tripped lockout and alarm – manual reset (Price is per pump) (15)
  • EHSM (Electronic heat and seal monitor), (price is per pump) (16)
  • Minicas (Price is per pump) -free issued (16a)
  • Minicas (Price is per pump) (16b)
  • EHSM c/w PTC relay (price is per pump) (17)
Optional Features for Power Include:

  • 15 AMP GFI receptacle for 230/460/575V 3φ panels (neutral not available) (18)
  • GFI receptacle for 1φ and 120/208/3/60 panels (neutral is available) (19)
  • Dexon heater/blower option (Dexon status board free issued) (20)
  • 120V breaker for pit light/vent fan for 230/460/575V 3φ panels (no neutral) (21)
  • 120V breaker for pit light/vent fan for 1φ and 120/208/3/60 panels (with neutral) (22)
  • Control transformer c/w fusing for 1φ or 208/3/60 (23)
  • Lightning arrestor complete with fusing for 1φ (24)
  • Lightning arrestor complete with fusing for 3φ (25)
  • Hoffman heater/blower c/w adjustable thermostat, 200W, 120V AC (26)
  • 125W Strip heater and thermostat (27)
  • Voltage phase monitor with fusing (28)
  • Two power sources with power transfer circuitry for control (29)
  • Power failure alarm and dry contacts (30)
Optional Features for Level and Pressure Control Include:

  • Intrinsically safe circuitry for 1 float (31)
  • Intrinsically safe circuitry for 2 floats (32)
  • Intrinsically safe circuitry for 3 floats (33)
  • Intrinsically safe circuitry for 4 floats (34)
  • Intrinsically safe circuitry for 5 floats (35)
  • Single float backup system c/w 3 timers (36)
  • Two float backup (36a)
  • Pressure switches operation (pressure switches are in customer’s scope) (37)
  • Allen Bradley 836-C7A pressure switch (38)
  • EBS1 pressure controller with in line 0-10VDC pressure transducer with 5 M cable (39)
  • EBS2 pressure controller with in line 4-20mA pressure transducer with 5 M cable and analog card (40)
  • ELM level controller with submersible pressure transducer with 10M cable and analog card (41)
  • ELM level controller and analog card- Pressure transducer free issued (41a)
  • Intrinsically safe barrier for ELM (42)
  • Dosing circuitry using dosing timer (43)
  • EDM dosing controller (44)
  • Low level alarm, auto reset pump and auto reset alarm (45)
  • Low level alarm, auto reset pump and manual reset alarm (46)
  • Non concurrent start timer (47)
  • Three float circuitry, manual reset alarm (48)
  • Four float circuitry, manual reset alarm (49)
  • Special float sequence (stop, start, high level, override) (50)
Optional Features for Panels Include:

  • Elapsed time meter (non-resettable), price is per pump (51)
  • Cycle counter (non-resettable), price is per pump (52)
  • 22mm operator and pilot lights (Price is per pilot light) (53)
  • P1 – Automatic alternation – P2 circuitry using toggle switch (54)
  • P1 – Automatic alternation – P2 circuitry using 22mm selector switch (55)
  • Stainless Steel Enclosure 4x (56)
  • Fiberglass Enclosure 4x (57)
  • Painted Steel Enclosure 4x (58)
  • Capacitors and Relays (price is per pump) -free issued (C)
TECP Outdoor Panel - Ideal for Industrial Wastewater Management

Standard Features Include:

  • NEMA 4 enclosure
  • Main disconnect
  • Pad lockable hasp
  • Fully hinged inner door
  • Coordinated Motor Starters are resettable from the inner door
  • 120V control circuit or transformer
  • IEC rated motor contactor
  • Overload protection
  • Float control logic
  • Dry contacts for remote alarm
  • Pump terminal blocks
  • Float switch terminal blocks
  • Dry contact terminal blocks
  • Ground lugs
  • Pump run lights
  • High level light
  • Hand-Off-Auto switches
  • Alarm Test and Acknowledge switches
  • Visual high water alarm globe with flasher
  • Steel enclosures

Related Products