YOU'RE INVITED! Join us for our Wireworks OPEN HOUSE October 14, 2021 at 10AM. RSVP to EBolyea@Tulsar.com

X

TECP Outdoor Series Panel

TECP Outdoor Series Panel

Features and Benefits

Standard Features include:

  • NEMA 4 enclosure
  • Main disconnect
  • Pad lockable hasp
  • Fully hinged inner door
  • Coordinated Motor Starters are resettable from the inner door
  • 120V control circuit or transformer
  • IEC rated motor contactor
  • Overload protection
  • Float control logic
  • Dry contacts for remote alarm
  • Pump terminal blocks
  • Float switch terminal blocks
  • Dry contact terminal blocks
  • Ground lugs
  • Pump run lights
  • High level light
  • Hand-Off-Auto switches
  • Alarm Test and Acknowledge switches
  • Visual high water alarm globe with flasher
  • Steel enclosures

Optional Features

Optional Features Include:

Alarms and Status

  • Alarm Bell (Nema 1) (1)
  • Alarm Horn (Nema 4) (2)
  • Wet contacts for remote alarm (3)
  • Extra dry contacts for remote alarm (4)
  • Dry contacts for equipment status (5)
  • 4 Channel landline Autodialer with battery backup (6)
  • 8 Channel Cellular Autodialer with built in battery backup (7)

Pump Monitoring

  • Pump seal leak alarm (Price is per pump) (8a-Single probe; 8b-Dual Probe; 8c- Single or Dual probe) (8)
  • Pump heat sensor cut-out – auto reset (Price is per pump) (9)
  • Pump heat sensor cut-out and alarm – auto reset (Price is per pump) (10)
  • Pump heat sensor lockout, transfer and alarm-manual reset (price is per pump) (Transfer on duplex panels only) (11)
  • Pump overload fault lockout, transfer and alarm- manual reset (price is per pump) (Transfer on duplex panels only) (12)
  • Pump undercurrent fault lockout and alarm- manual reset (Price is per pump) (Transfer on duplex panels only) (13)
  • Fuse blown fault lockout and alarm – manual reset (Price is per pump) (14)
  • Circuit breaker tripped lockout and alarm – manual reset (Price is per pump) (15)
  • EHSM (Electronic heat and seal monitor), (price is per pump) (16)
  • Minicas (Price is per pump) -free issued (16a)
  • Minicas (Price is per pump) (16b)
  • EHSM c/w PTC relay (price is per pump) (17)

Power

  • 15 AMP GFI receptacle for 230/460/575V 3φ panels (neutral not available) (18)
  • GFI receptacle for 1φ and 120/208/3/60 panels (neutral is available) (19)
  • Dexon heater/blower option (Dexon status board free issued) (20)
  • 120V breaker for pit light/vent fan for 230/460/575V 3φ panels (no neutral) (21)
  • 120V breaker for pit light/vent fan for 1φ and 120/208/3/60 panels (with neutral) (22)
  • Control transformer c/w fusing for 1φ or 208/3/60 (23)
  • Lightning arrestor complete with fusing for 1φ (24)
  • Lightning arrestor complete with fusing for 3φ (25)
  • Hoffman heater/blower c/w adjustable thermostat, 200W, 120V AC (26)
  • 125W Strip heater and thermostat (27)
  • Voltage phase monitor with fusing (28)
  • Two power sources with power transfer circuitry for control (29)
  • Power failure alarm and dry contacts (30)

Level and Pressure Control

  • Intrinsically safe circuitry for 1 float (31)
  • Intrinsically safe circuitry for 2 floats (32)
  • Intrinsically safe circuitry for 3 floats (33)
  • Intrinsically safe circuitry for 4 floats (34)
  • Intrinsically safe circuitry for 5 floats (35)
  • Single float backup system c/w 3 timers (36)
  • Two float backup (36a)
  • Pressure switches operation (pressure switches are in customer’s scope) (37)
  • Allen Bradley 836-C7A pressure switch (38)
  • EBS1 pressure controller with in line 0-10VDC pressure transducer with 5 M cable (39)
  • EBS2 pressure controller with in line 4-20mA pressure transducer with 5 M cable and analog card (40)
  • ELM level controller with submersible pressure transducer with 10M cable and analog card (41)
  • ELM level controller and analog card- Pressure transducer free issued (41a)
  • Intrinsically safe barrier for ELM (42)
  • Dosing circuitry using dosing timer (43)
  • EDM dosing controller (44)
  • Low level alarm, auto reset pump and auto reset alarm (45)
  • Low level alarm, auto reset pump and manual reset alarm (46)
  • Non concurrent start timer (47)
  • Three float circuitry, manual reset alarm (48)
  • Four float circuitry, manual reset alarm (49)
  • Special float sequence (stop, start, high level, override) (50)

Panels

  • Elapsed time meter (non-resettable), price is per pump (51)
  • Cycle counter (non-resettable), price is per pump (52)
  • 22mm operator and pilot lights (Price is per pilot light) (53)
  • P1 – Automatic alternation – P2 circuitry using toggle switch (54)
  • P1 – Automatic alternation – P2 circuitry using 22mm selector switch (55)
  • Stainless Steel Enclosure 4x (56)
  • Fiberglass Enclosure 4x (57)
  • Painted Steel Enclosure 4x (58)
  • Capacitors and Relays (price is per pump) -free issued (C)