Optional Features Include:
Alarms and Status
- Alarm Bell (Nema 1) (1)
- Alarm Horn (Nema 4) (2)
- Wet contacts for remote alarm (3)
- Extra dry contacts for remote alarm (4)
- Dry contacts for equipment status (5)
- 4 Channel landline Autodialer with battery backup (6)
- 8 Channel Cellular Autodialer with built in battery backup (7)
Pump Monitoring
- Pump seal leak alarm (Price is per pump) (8a-Single probe; 8b-Dual Probe; 8c- Single or Dual probe) (8)
- Pump heat sensor cut-out – auto reset (Price is per pump) (9)
- Pump heat sensor cut-out and alarm – auto reset (Price is per pump) (10)
- Pump heat sensor lockout, transfer and alarm-manual reset (price is per pump) (Transfer on duplex panels only) (11)
- Pump overload fault lockout, transfer and alarm- manual reset (price is per pump) (Transfer on duplex panels only) (12)
- Pump undercurrent fault lockout and alarm- manual reset (Price is per pump) (Transfer on duplex panels only) (13)
- Fuse blown fault lockout and alarm – manual reset (Price is per pump) (14)
- Circuit breaker tripped lockout and alarm – manual reset (Price is per pump) (15)
- EHSM (Electronic heat and seal monitor), (price is per pump) (16)
- Minicas (Price is per pump) -free issued (16a)
- Minicas (Price is per pump) (16b)
- EHSM c/w PTC relay (price is per pump) (17)
Power
- 15 AMP GFI receptacle for 230/460/575V 3φ panels (neutral not available) (18)
- GFI receptacle for 1φ and 120/208/3/60 panels (neutral is available) (19)
- Dexon heater/blower option (Dexon status board free issued) (20)
- 120V breaker for pit light/vent fan for 230/460/575V 3φ panels (no neutral) (21)
- 120V breaker for pit light/vent fan for 1φ and 120/208/3/60 panels (with neutral) (22)
- Control transformer c/w fusing for 1φ or 208/3/60 (23)
- Lightning arrestor complete with fusing for 1φ (24)
- Lightning arrestor complete with fusing for 3φ (25)
- Hoffman heater/blower c/w adjustable thermostat, 200W, 120V AC (26)
- 125W Strip heater and thermostat (27)
- Voltage phase monitor with fusing (28)
- Two power sources with power transfer circuitry for control (29)
- Power failure alarm and dry contacts (30)
Level and Pressure Control
- Intrinsically safe circuitry for 1 float (31)
- Intrinsically safe circuitry for 2 floats (32)
- Intrinsically safe circuitry for 3 floats (33)
- Intrinsically safe circuitry for 4 floats (34)
- Intrinsically safe circuitry for 5 floats (35)
- Single float backup system c/w 3 timers (36)
- Two float backup (36a)
- Pressure switches operation (pressure switches are in customer’s scope) (37)
- Allen Bradley 836-C7A pressure switch (38)
- EBS1 pressure controller with in line 0-10VDC pressure transducer with 5 M cable (39)
- EBS2 pressure controller with in line 4-20mA pressure transducer with 5 M cable and analog card (40)
- ELM level controller with submersible pressure transducer with 10M cable and analog card (41)
- ELM level controller and analog card- Pressure transducer free issued (41a)
- Intrinsically safe barrier for ELM (42)
- Dosing circuitry using dosing timer (43)
- EDM dosing controller (44)
- Low level alarm, auto reset pump and auto reset alarm (45)
- Low level alarm, auto reset pump and manual reset alarm (46)
- Non concurrent start timer (47)
- Three float circuitry, manual reset alarm (48)
- Four float circuitry, manual reset alarm (49)
- Special float sequence (stop, start, high level, override) (50)
Panels
- Elapsed time meter (non-resettable), price is per pump (51)
- Cycle counter (non-resettable), price is per pump (52)
- 22mm operator and pilot lights (Price is per pilot light) (53)
- P1 – Automatic alternation – P2 circuitry using toggle switch (54)
- P1 – Automatic alternation – P2 circuitry using 22mm selector switch (55)
- Stainless Steel Enclosure 4x (56)
- Fiberglass Enclosure 4x (57)
- Painted Steel Enclosure 4x (58)
- Capacitors and Relays (price is per pump) -free issued (C)